- FER Strumenti VIỆT NAM
- NUOVA FIMA VIETNAM
- Dover Flexo Electronics
- FTI Flow Technology
- OHKURA VIETNAM
- ASHCROFT VIỆT NAM
- DWYER VIỆT NAM
- BROOKS INSTRUMENT
- VEGA VIETNAM
- SCHENCK PROCESS VIETNAM
- FIREYE VIETNAM
- MOOG VIETNAM
- K0GANEI VIETNAM
- QUALITEST VIETNAM
- TECLOCK VIETNAM
- CELLAPORT PT VIETNAM
- WISE VIETNAM
- AT2E VIETNAM
- TEMA VIETNAM
- Taihei Boeki VIỆT NAM
- CEIA VIETNAM
- KNICK VIETNAM
- PRESSURE TECH VIỆT NAM
- ME-Meßsysteme VIỆT NAM
- TDK LAMBDA
- KLOEPPER-THERM VIỆT NAM
- BIRCHER VIETNAM
- IBA VIETNAM
- SORINC VIET NAM
- MONTECH VIET NAM
- BURKERT VIETNAM
- NIRECO VIETNAM
- CEMB VIETNAM
- MARK-10 VIETNAM
- GASTRON VIETNAM
- RED LION VIETNAM
- MATSUSHIMA VIETNAM
- TAKENAKA VIETNAM
- PORA VIETNAM
- GEMU VIETNAM
- BECKHOFF VIETNAM
THIẾT BỊ GIÁM SÁT RUNG TM1 CEMB/CEMB VIETNAM
-
- Thông Tin Sản Phẩm
- Đánh Giá
Vibration monitoring TM1 CEMB
Main characteristics
Input vibration signals from velocity or acceleration transducer
Input signals from no-contact transducer or photocell (NPN) for phase or rotation measurements
Provision for installing low and/or high band-pass filters for selecting frequency of the input signals (nb: frequency of the low band-pass filter should be at least double that of the high band-pass filter)
Output signals of analog type proportional to the measured current signal (4 to 20 mA) or else voltage signal (0 to 10 Vdc) independent for each measuring channel
Digital output signals, presettable over the entire measurement range (for alarm and/or trip contacts of the machinery)
Digital output signal for self-diagnostics alarm with logic presettable by the user
Real time local display on digital readout of the value measured with selection by the user of the channel to be displayed.
Real time local display on LEDs regarding alarm status and self-diagnostics
Provision for interfacing with vibration analyzer (BNC)
Provision for interfacing with P.C. (RS 485)
Possibility of user operating on the alarm signals with regards to:
- time delay in tripping the alarm threshold
- alarm threshold multiplier
- relay impulse time
- type of relay operation (NR or NE)
- type of relay memorization
- relay inhibition when switching on
- relay operation bypass
- relay reset
- selection of mode of relay operation
Provision for varying the preset parameters by means of local push buttons (Fnn functions) or by P.C. via serial link RS485 (dedicated program)
Fixed on standardized DIN rail
Specifications: TM1
- Power supply:
24Vdc ±10%
115/230 Vac 50/60 Hz
- Current drawn:
0.25 A max. (for Vdc power supply)
0.40 A max. (for Vac power supply)
- Measuring channels: two, max. (Ch.A and Ch.B)
- Field acquirable signals:
from velocity transducers sensitivity 21.2 mV / mm/s
from acceleration transducers sensitivity 100 mV/g
- Analog outputs:
OUT-A = 4 to 20 mA max. load 600 ohm or else 0 to 10 Vdc min. load 10 Kohm
OUT-B = 4 to 20 mA max. load 600 ohm or else 0 to 10 Vdc min. load 10 Kohm
- Digital outputs:
AL1-A = 1 SPDT (8A-250Vac) on RL1 alarm threshold
AL2-A = 1 SPDT (8A-250Vac) on RL2 alarm threshold
AL1-B = 1 SPDT (8A-250Vac) on RL3 alarm threshold
AL2-B = 1 SPDT (8A-250Vac) on RL4 alarm threshold
OK = 1 ON-OFF (8A-250Vac) on RL5 self-diagnostics
- Transd. output signal:
BNC-A = panel socket
BNC-B = panel socket
- Serial output: RS 485
Connection wiring diagram and overall dimensions